The testo 350 is a rugged, easy-to-use exhaust gas analyzer designed to meet the highest demands when it comes to carrying out precise industrial emission measurements and providing proper data administration. The Analysis Box can be operated with up to 6 gas sensors, 5 of which are optional. This allows you to select freely from sensors for CO, NO, NO2, SO2, H2S, CxHy and CO2.
Stock
Limited
Custom Pricing
Get A Quote
Stock
Limited
Custom Pricing
Get A QuoteIdeal for professional flue gas analysis and industrial emissions measurement on industrial engines, burners, gas turbines and in thermal processes: the testo 350 flue gas analyzer performs a variety of measuring and analysis tasks, impresses over the long term thanks to its heavy-duty industrial design and is also suitable for complex data acquisition.
Specification
Temperature - NTC | |
---|---|
Measuring range |
-20 to +50 °C |
Accuracy |
±0.2 °C (-10 to +50 °C) |
Resolution |
0.1 °C (-20 to +50 °C) |
Ambient temperature probe
Temperature - TC Type K (NiCr-Ni) | |
---|---|
Measuring range |
-200 to +1370 °C |
Accuracy |
±0.4 °C (-100 to +200 °C) ±1 °C (-200 to -100.1 °C) ±1 °C (200.1 to +1370 °C) |
Resolution |
0.1 °C (-200 to +1370 °C) |
Temperature - TC Type S (Pt10Rh-Pt) | |
---|---|
Measuring range |
0 to +1760 °C |
Accuracy |
±1 °C (0 to +1760 °C) |
Resolution |
0.1 °C (0 to +1760 °C) |
Differential Pressure - Piezoresistive | |
---|---|
Measuring range |
-40 to +40 hPa -200 to +200 hPa |
Accuracy |
±1.5 % of mv (-40 to -3 hPa) ±1.5 % of mv (+3 to +40 hPa) ±0.03 hPa (-2.99 to +2.99 hPa) ±1.5 % of mv (-200 to -50 hPa) ±1.5 % of mv (+50 to +200 hPa) ±0.5 hPa (-49.9 to +49.9 hPa) |
Resolution |
0.01 hPa (-40 to +40 hPa) 0.1 hPa (-200 to +200 hPa) |
Absolute Pressure | |
---|---|
Measuring range |
600 to +1150 hPa |
Accuracy |
±10 hPa |
Resolution |
1 hPa |
Flue gas O₂ | |
---|---|
Measuring range |
0 to +25 Vol.% |
Accuracy |
±0.8% of fsv (0 to +25 Vol.%) |
Resolution |
0.01 Vol.% (0 to +25 Vol.%) |
Reaction time t₉₀ |
20 s (t₉₅) |
Flue gas CO (with H₂-compensation) | |
---|---|
Measuring range |
0 to +10000 ppm |
Accuracy |
±5 % of mv (+200 to +2000 ppm) ±10 % of mv (+2001 to +10000 ppm) ±10 ppm (0 to +199 ppm) |
Resolution |
1 ppm (0 to +10000 ppm) |
Reaction time t₉₀ |
40 s |
H₂ only as an indicator
Flue gas COlow (with H₂-compensation) | |
---|---|
Measuring range |
0 to 500 ppm |
Accuracy |
±5 % of mv (+40 to +500 ppm) ±2 ppm (0 to +39.9 ppm) |
Resolution |
0.1 ppm (0 to +500 ppm) |
Reaction time t₉₀ |
40 s |
H₂ only as an indicator
Flue gas NO | |
---|---|
Measuring range |
0 to +4000 ppm |
Accuracy |
±5 % of mv (+100 to +1999 ppm) ±10 % of mv (+2000 to +4000 ppm) ±5 ppm (0 to +99 ppm) |
Resolution |
1 ppm (0 to +4000 ppm) |
Reaction time t₉₀ |
30 s |
Flue gas Nolow | |
---|---|
Measuring range |
0 to +300 ppm |
Accuracy |
±5 % of mv (+40 to +300 ppm) ±2 ppm (0 to +39.9 ppm) |
Resolution |
±0.1 ppm (0 to +300 ppm) |
Reaction time t₉₀ |
30 s |
Flue gas NO₂ | |
---|---|
Measuring range |
0 to +500 ppm |
Accuracy |
±5 % of mv (+100 to +500 ppm) ±5 ppm (0 to +99.9 ppm) |
Resolution |
0.1 ppm (0 to +500 ppm) |
Reaction time t₉₀ |
40 s |
Flue gas SO₂ | |
---|---|
Measuring range |
0 to +5000 ppm |
Accuracy |
±5 % of mv (+100 to +2000 ppm) ±10 % of mv (+2001 to +5000 ppm) ±5 ppm (0 to +99 ppm) |
Resolution |
1 ppm (0 to +5000 ppm) |
Reaction time t₉₀ |
30 s |
Flue gas degree of effectivity, Eta (calculated) | |
---|---|
Measuring range |
0 to +120 % |
Resolution |
0.1 % (0 to +120 %) |
Flue gas loss (calculated) | |
---|---|
Measuring range |
0 to +99.9 % |
Resolution |
0.1 % (0 to +99.9 %) |
Flue gas dewpoint (calculated) | |
---|---|
Measuring range |
0 to +99.9 °Ctd |
Resolution |
0.1 °Ctd (0 to +99.9 °Ctd) |
Flue gas CO₂ calculation (calculated from O₂) | |
---|---|
Measuring range |
0 to CO₂ max |
Accuracy |
calculated from O₂ ±0.2 Vol.% |
Resolution |
0.01 Vol.% |
Flue gas H₂S | |
---|---|
Measuring range |
0 to +300 ppm |
Accuracy |
±5 % of mv (+40 to +300 ppm) ±2 ppm (0 to +39.9 ppm) |
Resolution |
0.1 ppm (0 to +300 ppm) |
Reaction time t₉₀ |
35 s |
Flue gas CO₂ - NDIR | |
---|---|
Measuring range |
0 to +50 Vol.% |
Accuracy |
±0.3 Vol.% + 1 % of mv (0 to 25 Vol.%) ±0.5 Vol.% + 1.5 % of mv (>25 to 50 Vol.%) |
Resolution |
0.01 Vol.% (0 to 25 Vol.%) 0.1 Vol.% (> 25 Vol.%) |
Reaction time t₉₀ |
10 s |
Velocity / Volume flow | |
---|---|
Measuring range |
0 to +40 m/s |
Resolution |
0.1 m/s (0 to +40 m/s) |
Methane (CH₄) | |
---|---|
Measuring range |
100 to 40000 ppm |
Accuracy |
< 400 ppm (100 to 4000 ppm) < 10 % of mv (> 4000 ppm) |
Resolution |
10 ppm |
Min. O₂ requirement in flue gas |
2 % + (2 x mV methane) |
Reaction time t₉₀ |
< 40 s |
Response factor |
1 |
Lower explosion limit (LEL) must be adhered to.
The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user.
Propane (C₃H₈) | |
---|---|
Measuring range |
100 to 21000 ppm |
Accuracy |
< 400 ppm (100 to 4000 ppm) < 10 % of mv (> 4000 ppm) |
Resolution |
10 ppm |
Min. O₂ requirement in flue gas |
2 % + (5 x mV propane) |
Reaction time t₉₀ |
< 40 s |
Response factor |
1.5 |
Lower explosion limit (LEL) must be adhered to.
The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user.
Butane (C₄H₁₀) | |
---|---|
Measuring range |
100 to 18000 ppm |
Accuracy |
< 400 ppm (100 to 4000 ppm) < 10 % of mv (> 4000 ppm) |
Resolution |
10 ppm |
Min. O₂ requirement in flue gas |
2 % + (6.5 x mV butane) |
Reaction time t₉₀ |
< 40 s |
Response factor |
2 |
Lower explosion limit (LEL) must be adhered to.
The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user.
General technical data | |
---|---|
Weight |
4800 g |
Dimensions |
330 x 128 x 438 mm |
Operating temperature |
-5 to +45 °C |
Product-/housing material |
ABS |
Protection class |
IP40 |
Connectable probes |
1 x combustion air temperature probe; 1 x flue gas probe; 1 x temperature probe; 1 x differential pressure |
Product colour |
Black |
Battery life |
5 h |
Battery type |
lithium batteries |
DC electric tension input |
11V to 40V |
Power supply |
AC mains unit 100V to 240V (50 to 60 Hz) |
Dewpoint calculation |
0 °Ctd; 99 °Ctd |
Hose length |
16.2 m (corresponds to 5 probe hose extensions) |
Max. dust load |
20 g/m³ dust in flue gas |
Max. humidity load |
70 °C dewpoint temperature |
Max. neg. press./flue gas |
-300 mbar |
Max. pos. press./flue gas |
50 mbar |
Pump flow |
1 l/min. with through-flow monitoring |
Trigger input |
Voltage 5 to 12 Volt (rising or trailing edge) pulse width > 1 sec load: 5 V/max, 5 mA, 12 V/max. 40 mA |
Maximum memory |
250,000 readings |
Interface |
data bus; Bluetooth®; USB; IR/IRDA interface; Mains connection; trigger input; Differential Pressure; probe input/ probe inputs; DC-voltage input; dilution gas inlet for measurement range extension |
Storage temperature |
-20 to +50 °C |
Testo 175 T2 2-Channel Temperature Data Logger with Dual NTC
Testo 176 T1 1-Channel Metal Temperature Data Logger
Testo 890-2 Thermal Imaging Camera, 640 x 480 FPA, NETD < 40 mK
Testo 865S Thermal Imager, 160 x 120, 100 mK
Testo 175 T1 1-Channel Temperature Data Logger
Testo 174H 2-Channel Temperature/Humidity Data Logger Kit with USB interface
Testo 176-T3 4-Channel Metal Temperature Data Logger with 4 external TC
testo 330i advanced set - flue gas analyzer set
Testo 176-P1 5-Channel Pressure/Temperature/Humidity Data Logger with external NTC
Testo 184-G1 USB Temperature, Humidity and Shock Data Logger with LCD
Testo 175 T3 2-Channel Temperature Data Logger with 2 external TC
Testo 176-T2 2-Channel Temperature Data Logger with 2 external RTD
Testo 605-H1 Thermo-Hygrometer w/ Dewpoint Calculation
Testo 174T 1-Channel Temperature Data Logger Kit with USB interface
testo 350 MARITIME - Exhaust gas analyzer for diesel ship engines
KUKA Articulated robot KR IONTEC
Keystone Pipe Handling Tools Beckets & Bails
Type CD Drill Pipe Elevators API Spec 8A/8C For Drill Collar/Casing/Tubing
Coriolis flow transmitter CFT34A
Blancett 900 Series Positive Displacement Flow Meter
GF Signet 515 Rotor-X Paddle Wheel Flow Sensor
GF Signet 2536 Rotor-X Paddle Wheel Flow Sensor
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited
DHI A/S, our affiliates, suppliers and business partners use cookies to provide the best possible service to our website users. Cookies are used for:
Marketing allWe will not place cookies from this website unless you consent hereto (except for technical cookies
functional allWe will not place cookies from this website unless you consent hereto (except for technical cookies
statistical allWe will not place cookies from this website unless you consent hereto (except for technical cookies
normaal allWe will not place cookies from this website unless you consent hereto (except for technical cookies
When you visit any website, it may store or retrieve information on your browser, mostly in the form of cookies. This information might be about you, your preferences or your device and is mostly used to make the site work as you expect it to. The information does not usually directly identify you, but it can give you a more personalized web experience. Because we respect your right to privacy, you can choose not to allow some types of cookies. Click on the different category headings to find out more and change our default settings. However, blocking some types of cookies may impact your experience of the site and the services we are able to offer. You can get more information by going to our Privacy Policy or Statement in the footer of the website.
These cookies are necessary for the website to function and cannot be switched off in our systems. They are usually only set in response to actions made by you which amount to a request for services, such as setting your privacy preferences, logging in or filling in forms. You can set your browser to block or alert you about these cookies, but some parts of the site will not then work. These cookies do not store any personally identifiable information.
Cookies detailsThese cookies allow us to count visits and traffic sources so we can measure and improve the performance of our site. They help us to know which pages are the most and least popular and see how visitors move around the site. Most of these cookies collect and process aggregated (anonymized) information without identifying individuals. If you do not allow these cookies we will not know when you have visited our site, and will not be able to monitor its performance.
Cookies detailsThese cookies enable the website to provide enhanced functionality and personalisation. They may be set by us or by third party providers whose services we have added to our pages. If you do not allow these cookies then some or all of these services may not function properly.
Cookies detailsThese cookies may be set through our site by our advertising partners. They may be used by those companies to build a profile of your interests and show you relevant adverts on other sites. They do not store directly personal information, but are based on uniquely identifying your browser and internet device. If you do not allow these cookies, you will experience less targeted advertising.
Cookies detailsPowered byOneTrust
Check all added RFQ in one place, hit the button to show all added RFQ.
Submit RFQ