NG # 00490-HW-Fluke-053
The new TS®100 PRO Cable Fault Finder with PowerBT™ Bridge Tap Detect not only provides open/short circuit detection – to 8,000 feet (2.4 kilometres) – but is also a telecom technician’s first line of defense against bridge taps. Because bridge taps are a significant source of DSL network performance problems, they need to be identified and fixed quickly before causing customer attrition.
Stock
Limited
Custom Pricing
Get A Quote
Stock
Limited
Custom Pricing
Get A QuoteAn essential five-in-one tool, the TS100 PRO also gives users a built-in toner with five different tones and patented SmartTone® for exact pair identification and reports AC/DC voltage from just one end of any two conductor wires, telephone wires, security wires or coax cables. This time-saving multi-tool is so affordable every technician can have one.
Specification
Maximum Length | 8,000 feet (2,438 meters) on certain cable types, 4,000 feet (1,220 meters) on most cable types, and 500 feet (152 meters) on cables with high loss. The tester shows -Err if the cable is too long to be correctly measured. |
Representative Maximum Cable Length | 8,000 feet (2,438 meters): CAT-3 Twisted Pair 8,000 feet (2,438 meters): CAT-5 Twisted Pair 6,000 feet (1,830 meters): 12/2 AC Wire 3,000 feet (900 meters): RG-6/U TV Coax 1,500 feet (457 meters): RG-174/U Coax |
Minimum Length | No minimum length (can read a bridge tap at 0 feet/meters). Minimum non-zero reading is 2 feet or 1 meter. |
Length Accuracy | ±2 feet (±0.6 m) for cables less than 10 feet (3 m) ±5 feet (±2 m) for cables longer than 10 feet (3 m) and shorter than 200 feet (60 m) +/-3%+/-5 feet (±2 m) for cables longer than 200 feet (60 m) |
Distance to Bridge Tap | 0 feet to 3,200 feet (975 meters) |
Minimum Length of Bridge Tap | 10% of the distance to the bridge tap. Dependant on the cable characteristics. |
Measurement Rate | Maximum of 4 complete measurements per second, decreasing to 2 seconds per measurement based on cable size and uniformity. |
VOP | Adjustable from 20 to 99, saved in flash memory. |
Test Technology | Time Domain Reflectometry (TDR) with 100 Ω drive impedance, 6v maximum pulse height. |
Cable Type | Virtually all two or more conductor cables. |
Power | 4 AA alkaline batteries. |
Reverse Battery Protection | No damage to the tester will occur if the batteries are installed backwards. |
Battery Life | 35 hours (typical) |
Low Battery Indication | LED display alternates between LO and bAtt when the battery voltage falls below 4.5v. |
Maximum Output Voltage | 4 voltage peak |
Maximum Isolation Voltage | 250 volts RMS |
Voltage Measurements | Range: 0 volts AC to 115 volts AC; 0 volts DC to ±150 volts DC AC voltage ≥90 volts or DC voltage ≥100 volts causes high voltage warnings to show on the display |
High Voltage Detection | AC voltage detected to 115 volts; DC voltage detected to ±150 volts. |
SmartTone® (5-tones) Range | 7,000 feet (2,134 meters) |
Toner Range | 52,800 feet (16,093 meters) |
Tone Injection | Approximately 1 kHz at an amplitude of 80% of battery voltage. Variable frequency and cadence. Tone characteristics change as cable condition changes to “normal-open” from any other condition. |
Impedance Range | 35 Ω to 330 Ω with auto-compensation within this range. Cables with impedances outside this range will not be properly tested and may produce erratic or incorrect readings. |
Temperature Range | Operating: 32°F to 104°F (0°C to 40°C) Storage: 32°F to 131°F (0°C to 55°C) |
Humidity | Operating: 20% to 80% relative humidity Storage: 0% to 100% relative humidity |
Operating Humidity | 80% maximum at 86°F (30°C ) 50% maximum at 104°F (40°C ) |
Operating Altitude | 9,843 ft max (3,000 m max) |
Weight | 1 lb (454 grams) |
Dimensions | 7.4 in x 2.7 in x 1.4 in (18.8 cm x 6.9 cm x 3.6 cm) |
Safety | IEC 61010-1:2010; N10140 EMC: IEC/EN61326-1:2006 |
Certifications and Compliance | Conforms to relevant European Union directives Conforms to relevant Australian standards IEC/EN61010-1 CAN/CSA-C22.2 No. 1010.1-92 + CSA-C22.2 No. 1010.1B-97, UL/ANSI 3111-1 |
Notes | Patents 6160405, 6285195, 6323654, and 6509740. Specifications subject to change without notice. |
TS® 100 PRO Cable Fault Finder with PowerBT™ Bridge Tap Manual
Fluke Intrinsically Safe Calibrator - 707Ex (Discontinued)
Fluke Intrinsically Safe Pressure Module - 700PEx (Discontinued.)
Fluke SimpliFiber® Pro Optical Power Meter and Fiber Test Kits
Fluke Networks PTNX8-Cable Pocket Toner NX8 Cable Kit
Fluke Networks CFP-100-Q 120 CertiFiber Pro Quad Optical Loss Test Set
Fluke Networks CIQ-100 CableIQ Qualification Tester (Discontinued)
Veritas NetBackup 5340 - hard drive array
Veritas NetBackup 5340 - hard drive array
Advantech MIC-7700 Compact Fanless System with Intel Core i CPU Socket
17" SXGA Industrial Monitors with Resistive Touch Control, Direct HDMI, DP, and VGA Ports
MITAC INTEL TIGER LAKE I3-1115G4E FANLESS INDUSTRIAL EMBEDDED SYSTEM, VPRO, TPM 2.0
MITAC MP1-11TGS TIGER LAKE I7-1185G7E FANLESS INDUSTRIAL EMBEDDED SYSTEM, VPRO, TPM 2.0
Juniper Networks NFX250 Network Services Platform - application accelerator
Cisco Catalyst 9600 Series Networking Switch
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited