The 116 Digital Multimeter is tailored for professionals in the heating, ventilation, and air conditioning (HVAC) industry, offering specialized features to meet the unique needs of HVAC professionals
Stock
5
in stock
Custom Pricing
Get A Quote
Stock
5
in stock
Custom Pricing
Get A QuoteThe Fluke 116 also measures resistance, continuity, frequency, and capacitance. And the large white LED backlight makes it easy to see results even in poorly lit areas.
The Fluke 116 was specifically designed for HVAC professionals. It has everything you need to quickly troubleshoot problems with HVAC equipment and flame sensors, including a built-in thermometer to measure temperatures up to 400°C (752°F) and microamps to test flame sensors.
Maximum voltage between any terminal and earth ground | 600 V | |
Safety | IEC 61010-1: Pollution Degree 2 IEC 61010-2-033: CAT III 600V | |
Display | Digital: 6,000 counts, updates 4 per second | |
Bar graph | 33 segments, updates 32 per second | |
Operating temperature | -10°C to + 50°C | |
Storage temperature | -40°C to + 60°C | |
Battery type | 9 volt Alkaline, IEC 6LR61 | |
Battery life | 400 hours typical, without backlight | |
Accuracy Specifications | ||
DC millivolts | Range/resolution | 600.0 mV / 0.1 mV |
Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
DC volts | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V |
Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
Auto volts | Range/resolution | 600.0 V / 0.1 V |
Accuracy | 2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz) | |
AC millivolts1Â True RMS | Range/resolution | 600.0 mV / 0.1 mV |
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) | |
AC volts1Â True RMS | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V |
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) | |
Continuity | Range/resolution | 600 Ω / 1 Ω |
Accuracy | Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer. | |
Ohms | Range/resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ |
Accuracy | 0.9% + 1 | |
Range/Resolution | 40.00 MΩ / 0.01 MΩ | |
Accuracy | 5% + 2 | |
Diode Test | Range/resolution | 2.00 V / 0.001 V |
Accuracy | 0.9% + 2 | |
Capacitance | Range/resolution | 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF |
Accuracy | 1.9% + 2 | |
Range/resolution | > 1000 μF | |
Accuracy | 5% + 20% | |
Lo-Z Capacitance | Range | 1 nF to 500 μF |
Accuracy | 10% + 2 typical | |
Temperature² (Type-K thermocouple) | Range/resolution | -40°C to 400°C / 0.1°C |
Accuracy | 1% + 10² | |
Range/resolution | -40°F to 752°F / 0.2°F | |
Accuracy | 1% + 18² | |
AC μA true-rms (45 Hz to 500 Hz) | Range/resolution | 600.0 μA / 0.1 μA |
Accuracy | 1.5% + 3 | |
DC μamps | Range/resolution | 600.0 μA / 0.1 μA |
Accuracy | 1.0% + 2 | |
Hz (V or A input)² | Range/resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 Hz 50.00 kHz / 0.01 Hz |
Accuracy | 0.1% + 2 | |
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 3. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. 4. Temperature Range/Resolution: -40°F to 752°F / 0.2°F. | ||
Mechanical and General Specifications | ||
Size | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) | |
Weight | 550 g | |
Warranty | 3 years |
Fluke 116 Digital HVAC Multimeter Data Sheet
Fluke Networks CFP-100-Q 120 CertiFiber Pro Quad Optical Loss Test Set
Fluke 117 Electrician's Multimeter with Non-Contact VoltageFluke 117 Electrician's Multimeter with Non-Contact Voltage
Fluke Networks MT-8200-60-KIT IntelliToneâ„¢ Pro 200 Toner and Probe Kit
Fluke Networks LIQ-100 - LinkIQâ„¢ Cable+Network Tester
Fluke Networks PTNX8-Cable Pocket Toner NX8 Cable Kit
Fluke Intrinsically Safe Pressure Module - 700PEx (Discontinued.)
Advantech MIC-7700 Compact Fanless System with Intel Core i CPU Socket
17" SXGA Industrial Monitors with Resistive Touch Control, Direct HDMI, DP, and VGA Ports
MITAC INTEL TIGER LAKE I3-1115G4E FANLESS INDUSTRIAL EMBEDDED SYSTEM, VPRO, TPM 2.0
MITAC MP1-11TGS TIGER LAKE I7-1185G7E FANLESS INDUSTRIAL EMBEDDED SYSTEM, VPRO, TPM 2.0
Juniper Networks NFX250 Network Services Platform - application accelerator
Cisco Catalyst 9600 Series Networking Switch
Winmate Rugged laptop computer L140TG-3
Winmate Rugged laptop computer L140TG-4
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited
List Price
US $
Stock
Unlimited