Fluke 279 FC True-rms Thermal Multimeter

  • NG # 00455-HW-Fluke-018

  • MF # 4684050

Thermal imaging multimeters are a first-line troubleshooting tool for electrical equipment that can check hot spots on high-voltage equipment and transformers, and detect heating of fuses, wires, insulators, connectors, splices and switches. .

Manufactured By :
fluke

Stock
10 in stock

Need Help Ordering?
Call +88 01714243446

Custom Pricing

Get A Quote
Need Help Ordering?
Call +88 01714243446

Stock
10 in stock

Custom Pricing

Get A Quote

Overview

Compatible with iFlex® (a flexible current clamp) to expand your measurement capabilities and get into tight, hard to reach spaces for current measurement (up to 2500 A AC). The large full-color LCD screen makes for easier and clearer viewing of images and readings. The 10 hour+ rechargeable battery keeps you going all day long under normal conditions.

Specification

Specification

e/Resolution 600.0/0.1 mV
6.000/0.001 V
60.00/0.01 V
600.0/0.1 V
1000/1 V
Accuracy 45 to 65 Hz: 1.0 % + 3
65 to 200 Hz: 4.0% + 3
200 to 500 Hz: 15% + 3
AC mV
Range/Resolution 600.0/0.1 mV
Accuracy 45 to 500 Hz: 1.0% + 3
DC Voltage
Range/Resolution 6.000/0.001 V
60.00/0.01 V
600.0/0.1 V
1000/1 V
Accuracy 6, 60, 600 V: 0.09% + 2
1000 V: 0.15% + 2
DC mV
Range/Resolution 600.0/0.1 mV
Continuity
Range/Resolution 600/1 Ω
Accuracy Meter beeps at <25 Ω, beeper detects opens or shorts of 600 µs or longer
Resistance
Range/Resolution 600.0/0.1 Ω
6.000/0.001 kΩ
60.00/0.01 kΩ
600.0/0.1 kΩ
6.000/0.001 MΩ
50.00/0.01 MΩ
Accuracy 600 Ω: 0.5 % + 2
6 to 600 kΩ: 0.5 % + 1
50 MΩ: 1.5 % + 3
Diode Test
Range/Resolution 2.000/0.001 V
Accuracy 1% + 2
Capacitance
Range/Resolution 1000/1 nF
10.00/0.01 µF
100.0/0.1 µF
9999/1 µF
Accuracy 1000 nF to 100 µF: 1.2% + 2
9999 µF: 10% typical
AC Current
Range/Resolution 999.9/0.1 A
2500/1 A (with iFlex)
Accuracy 45 to 500 Hz: 3.0% + 5
Frequency
Range/Resolution 99.99/0.01 Hz
999.9/0.1 Hz
Accuracy 0.1% + 1
Input Characteristics
AC Voltage Input impedance (nominal): >10 MΩ <100 pF
Common mode rejection ratio (1 kΩ unbalance): >60 dB, DC to 60 Hz
Overload protection: 1100 V rms
DC Voltage Input impedance (nominal): >10 MΩ <100 pF
Common mode rejection ratio (1 kΩ unbalance): >120 dB at DC, 50 Hz or 60 Hz
Normal mode rejection: >60 dB at 50 Hz or 60 Hz
Overload protection: 1100 V rms
AC mV/DC mV Input impedance (nominal): >10 MΩ <100 pF
Common mode rejection ratio (1 kΩ unbalance): >120 dB at DC, 50 Hz or 60 Hz
Normal mode rejection: >60 dB at 50 Hz or 60 Hz
Overload protection: 1100 V rms
Resistance/Capacitance Open circuit test voltage: <2.7 V dc
Full scale voltage to 6 MΩ: <0.7 V dc
Full scale voltage 50 MΩ: <0.9 V dc
Typical short circuit current: <350 mA
Overload protection: 1100 V rms
Continuity/Diode Test Open circuit test voltage: <2.7 V dc
Full scale voltage: 2.000 V dc
Typical short circuit current: <1.1 mA
MIN/MAX Recording Accuracy
AC Functions 40 counts for changes > 900 ms in duration
DC Functions 12 counts for changes > 350 ms in duration
Infrared Camera Temperature
Temperature Range 14 to 392°F (-10 to 200°C )
Measurement Resolution 0.1°C
Temperature Measurement Yes, centerpoint
Accuracy ±5 °C or ±5 %, whichever is greater, at 25 °C (ambient) for target temperatures below 20 °C, add 0.05 °C for each °C
Emissivity 0.95 fixed
Image Performance
Resolution 102 x 77
Image Capture Frequency 8 Hz
Detector Type Uncooled vanadium oxide
Thermal sensitivity (NETD) ≤200 mK
Infrared Spectral Band 7.5 to 14 µm
Distance to Spot 162:1
Field of View 36 x 27°
Focus Mechanism Fixed focus
Image Presentation
Palette Ironbow
Level and Span Auto
Image Capture and Data Storage
Image Capture Image available for review before a save
Storage Medium Internal memory stores up to 100 images
Image Transfer Fluke Connect®/SmartView®
File Format is2
Display Size 3.5" (8.9 cm) diagonal

Other fluke Products

Fluke Ti480 PRO 60Hz Infrared Camera

fluke Safety & Security 00451-HW-Fluke-014

Fluke 87V MAX True-rms Digital Multimeter

fluke Computer & Electronics 00453-HW-Fluke-016

Fluke Networks PTNX8-Cable Pocket Toner NX8 Cable Kit

fluke Computer & Electronics 00481-HW-Fluke-044

Fluke TS® 22 Series Test Sets

fluke Computer & Electronics 00485-HW-Fluke-048

BUYERS WHO LIKED THIS PRODUCT ALSO LIKED

Veritas NetBackup 5340 - hard drive array

veritas Computer & Electronics 00004-SW-VER-001

Veritas NetBackup 5340 - hard drive array

veritas Computer & Electronics 00005-SW-VER-002

Veritas NetBackup 5340 - hard drive array

veritas Computer & Electronics 00006-SW-VER-003 20078-M4217

Emarson Box PC RXi2-XP

EMERSON Computer & Electronics 00101-HW-EMR-001 00101-HW-EMR-001
close
Your privacy

When you visit any website, it may store or retrieve information on your browser, mostly in the form of cookies. This information might be about you, your preferences or your device and is mostly used to make the site work as you expect it to. The information does not usually directly identify you, but it can give you a more personalized web experience. Because we respect your right to privacy, you can choose not to allow some types of cookies. Click on the different category headings to find out more and change our default settings. However, blocking some types of cookies may impact your experience of the site and the services we are able to offer. You can get more information by going to our Privacy Policy or Statement in the footer of the website.

All RFQ Product Added In Query!

Check all added RFQ in one place, hit the button to show all added RFQ.

Submit RFQ